# TA6000.

![TA6000](https://elvorka.com/assets/optimized/3767e02b99d59eea-1254-q92.webp)

Integrated system

# TA6000.

Battery and inverter in one cabinet, with PV input connectivity and three specified storage configurations. AC output options depend on the selected configuration.

INVERTER  Included

ENCLOSURE  Not specified

NOMINAL ENERGY  10.24–20.48 kWh

AC CONFIGURATION  120 V US / 230 V EU AC options

[Start your project ↗](https://elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | AC options (kW) |
| --- | --- | --- |
| TA6000-M2 | 10.24 | 6–10 |
| TA6000-M3 | 15.36 | 6–12 |
| TA6000-M4 | 20.48 | 6–12 |

Specify the correct market AC voltage and 50 / 60 Hz option. PV input: 11 kW for M2; 11–13.2 kW for M3/M4. No three-phase or split-phase capability is claimed.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| TA6000-M2 | 590 × 570 × 1880 / W × D × H | 244 |
| TA6000-M3 | 590 × 570 × 1880 / W × D × H | 286 |
| TA6000-M4 | 590 × 570 × 1880 / W × D × H | 328 |

Communication: RS485 / RS232 / CAN / Wi-Fi; Bluetooth optional
Temperature: Operating −20 to 60 °C

## Start with the room. Then size the backup.

A dry utility room, a seasonally hot garage and an unconditioned space need different installation decisions. Use the proposed room's temperature and exposure, alongside the loads and supply configuration, to narrow the product choice.

Temperature:  Operating −20 to 60 °C

ENCLOSURE  Not specified

01

### Dry utility room with selected backup circuits

Bring refrigeration, communications and selected lighting into one essential-load plan, rather than assuming every circuit will be backed up.

An integrated system keeps battery and inverter selection together. For TA6000, confirm the exact source-listed 120 V US configuration and supported circuits; split-phase capability is not established by the supplied material.

Which circuits and appliance starting loads need support?

- What is the actual supply configuration for this project?

02

### Garage with seasonal heat or cold

The garage's indoor conditions matter more than the outdoor forecast. Keep the cabinet in its designated equipment space with cooling paths and service access.

TR Pro lists charging from 0 to 55 °C (32 to 131 °F) and discharging from −20 to 60 °C (−4 to 140 °F). Optional self-heating needs exact-model confirmation; a discharge minimum does not establish a below-freezing charge rating.

What are the lowest and highest temperatures at the proposed battery location?

- Can condensation, wash water, heat sources or stored items affect the equipment space?

03

### Existing inverter or modular storage project

A battery-only option lets the storage choice follow the existing or planned inverter, provided the electrical and communication interfaces match.

TR Pro is 51.2 V; HP Ultra is a high-voltage stack. Match DC voltage, current settings and CAN/RS485 support. Ask the installer which configuration and project documentation are required.

What is the inverter's make, model and battery-voltage window?

- What AC output and documentation are required for the proposed installation?

Specifications

- Plan battery energy in kWh and inverter output in kW separately; whole-home backup requires a project-specific load and supply assessment.

- The supplied product literature does not establish US certification/listing status or 120/240 V split-phase capability. Request the exact configuration and documentation for the project.

- US temperature equivalents are unit conversions of the source Celsius values. They do not add environmental performance claims.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

The supplied brochure provides two labelled connection/breaker insets and internal cabinet/cell illustrations on printed pages 15-16. Crops avoid visible product logos without AI editing, repainting, or invented structure. Embedded views not visibly matched to the printed product page were excluded. These views do not establish pinouts, cable sizes, commissioning steps or installation compatibility.

[![Original terminal labels](https://elvorka.com/assets/product-details/ta-terminal-map.png)](https://elvorka.com/assets/product-details/ta-terminal-map.png)

Original terminal labels  Connection panel labelled for load, grid, optional generator, PV and communication.

[![Terminal panel close-up](https://elvorka.com/assets/product-details/ta-terminal-closeup.png)](https://elvorka.com/assets/product-details/ta-terminal-closeup.png)

Terminal panel close-up  Close-up of the cabinet terminal panel.

[![Original breaker labels](https://elvorka.com/assets/product-details/ta-breaker-map.png)](https://elvorka.com/assets/product-details/ta-breaker-map.png)

Original breaker labels  Battery, PV1, PV2, load and grid breakers in the illustrated compartment.

[![Breaker compartment close-up](https://elvorka.com/assets/product-details/ta-breaker-closeup.png)](https://elvorka.com/assets/product-details/ta-breaker-closeup.png)

Breaker compartment close-up  Circuit breakers within the cabinet's breaker compartment.

[![Upper cabinet and service bay](https://elvorka.com/assets/product-details/ta-service-bay.png)](https://elvorka.com/assets/product-details/ta-service-bay.png)

Upper cabinet and service bay  Upper cabinet compartment with the inverter and connection area.

[![Cell assembly detail](https://elvorka.com/assets/product-details/ta-cell-assembly.png)](https://elvorka.com/assets/product-details/ta-cell-assembly.png)

Cell assembly detail  Battery cell tops in a partial internal illustration.

### Know your interfaces.

#### Power connections

Load Output  Output position identified as Load Output in the brochure.

Grid Input  Connection position identified as Grid Input.

Generator Input (optional)  The generator input is explicitly marked optional in the original callout.

PV Input  PV connection area identified by the original callout.

PV1 Input Breaker  Breaker identified for PV1 Input.

PV2 Input Breaker  Breaker identified for PV2 Input.

#### Communication

Communication Port  Connection area labelled Communication Port. No protocol pin assignments are specified in this component view.

#### Controls & indicators

Battery Breaker  Breaker labelled for the battery section.

Load Breaker  Breaker identified for the load connection.

Grid Breaker  Breaker identified for the grid connection.

Source: Residential ESS brochure · PDF page 8 · printed pages 15-16

---