EU 230 V

Integrated system

EU 230 V.

An integrated inverter and 51.2 V LFP battery system. Three listed power-and-capacity configurations, with rated AC output of 6.2 or 12 kW.

INVERTER
Included
ENCLOSURE
IP21
NOMINAL ENERGY
10.24 / 16.076 kWh
AC CONFIGURATION
230 V AC / 50 or 60 Hz
Start your project ↗

Specifications

Model / configurationEnergy (kWh)Rated AC (kW)
6.2K-10/16KWH-EU10.246.2
6.2K-10/16KWH-EU16.0766.2
12K-16KWH-EU16.07612

6.2 kW AC configurations: 1 MPPT and max. PV 6.5 kW. 12 kW AC: 2 MPPT and max. PV 2 × 9 kW. Wi-Fi, parallel operation and CT options require confirmation.

ModelDimensions (mm)Approx. kg
6.2K-10/16KWH-EU552 × 254 × 1210 / L × W × H105
6.2K-10/16KWH-EU552 × 254 × 1210 / L × W × H130
12K-16KWH-EU552 × 254 × 1210 / L × W × H130

Communication: USB / RS485 / dry contact
Temperature: Charge 0 to 55 °C; discharge −20 to 55 °C

Start with the room. Then size the backup.

A dry utility room, a seasonally hot garage and an unconditioned space need different installation decisions. Use the proposed room's temperature and exposure, alongside the loads and supply configuration, to narrow the product choice.

Temperature:
Charge 0 to 55 °C; discharge −20 to 55 °C
ENCLOSURE
IP21
01

Dry utility room with selected backup circuits

Bring refrigeration, communications and selected lighting into one essential-load plan, rather than assuming every circuit will be backed up.

An integrated system keeps battery and inverter selection together. For TA6000, confirm the exact source-listed 120 V US configuration and supported circuits; split-phase capability is not established by the supplied material.

Which circuits and appliance starting loads need support?
  • What is the actual supply configuration for this project?
02

Garage with seasonal heat or cold

The garage's indoor conditions matter more than the outdoor forecast. Keep the cabinet in its designated equipment space with cooling paths and service access.

TR Pro lists charging from 0 to 55 °C (32 to 131 °F) and discharging from −20 to 60 °C (−4 to 140 °F). Optional self-heating needs exact-model confirmation; a discharge minimum does not establish a below-freezing charge rating.

What are the lowest and highest temperatures at the proposed battery location?
  • Can condensation, wash water, heat sources or stored items affect the equipment space?
03

Existing inverter or modular storage project

A battery-only option lets the storage choice follow the existing or planned inverter, provided the electrical and communication interfaces match.

TR Pro is 51.2 V; HP Ultra is a high-voltage stack. Match DC voltage, current settings and CAN/RS485 support. Ask the installer which configuration and project documentation are required.

What is the inverter's make, model and battery-voltage window?
  • What AC output and documentation are required for the proposed installation?
Specifications
  • Plan battery energy in kWh and inverter output in kW separately; whole-home backup requires a project-specific load and supply assessment.
  • The supplied product literature does not establish US certification/listing status or 120/240 V split-phase capability. Request the exact configuration and documentation for the project.
  • US temperature equivalents are unit conversions of the source Celsius values. They do not add environmental performance claims.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

Views and numbering come only from the supplied one-page EU brochure. The source does not provide pinouts, cable sizing, wiring procedures or a complete set of every exterior face. Native side-image resolution is modest. A rendered map improves the original vector labels, not the native photographic detail.

Original numbered interface map
Original numbered interface mapNumbered map of the AC, battery, PV and communication connections.
AC and battery connection side
AC and battery connection sideAC and battery connection side with cooling fans and the battery breaker.
AC and battery upper detail
AC and battery upper detailUpper AC connection area, cooling fans and BAT terminals.
PV and communication side
PV and communication sidePV and communication side, including the battery communication ports.
PV and communication upper detail
PV and communication upper detailVentilation grille above the PV and communication connection area.

Know your interfaces.

Power connections

AC input / output
The AC connection identified by number 1 in the original map.
AC input breaker
Breaker labelled for the AC input.
BAT+ / BAT-
Positive and negative battery terminals, as labelled in the source.
PV input
Input identified for the PV connection.

Communication

Parallel communication port
Communication connection labelled for parallel operation; configuration availability must be confirmed separately.
Dry contact control
Control interface labelled as dry contact in the brochure.
RS485 / BMS communication port
The communication connection named RS485/BMS in the original label.
Wi-Fi port
Port labelled Wi-Fi; the source specification lists Wi-Fi as an option requiring confirmation.
USB communication port
Communication interface labelled USB.
Battery communication ports
The source points to the group of three circular openings with label 11. It does not identify these as AC power inputs.

Controls & indicators

Battery breaker
Breaker identified for the battery section.

Source: EU 230 V product sheet · PDF page 1